The DM5E Series Ultrasonic Wall Thickness Gauge enables you to accomplish a large number of demanding tasks, especially with remaining wall thickness measurements on components subjected to corrosion and erosion. These gauges are smart, simple-to-use ultrasonic thickness gauges that offer big performance in a small lightweight package. Their compact size and ergonomic shape provide comfortable one-hand use. Equipment designed to monitor corrosion (deterioration of metals due to chemical reactions) in equipment such as pipes or tanks in the industry.
Features:
Range of measurement displays:
Normal: the thickness value appears as large digits in the centre of the display
MIN Scan: a minimum thickness scan that allows the user to run the probe over the wall surface. After the evaluation period, the minimum material thickness measured is displayed
MAX Scan: a maximum thickness scan is exactly the same as a MIN Scan apart from the fact that the maximum thickness measured is displayed
DIFF/RR%: compares the measured thickness with a user-specified nominal thickness – dimensional difference between the two values is displayed, as is the percentage difference
B-Scan: displays a graphic representation of a B-Scan showing minimum thickness values – graph is derived by measuring and recording at 1 point per second
Three levels – DM5E Basic, DM5E and DM5E DL
Thickness measurement under coating
User-friendly operator interface
New range of high performance probes
Flexible data processing
A range of measurement displays
Includes:
1X DM5E Basic Digital Ultrasonic Thickness Gauge .
Basic Instrument Includes:
Set (2 pcs.) AlMn dry cell batteries, AA, 1.5V, Bottle of
Couplant (100 g)
Manufacturer’s certificate
Brief instruction card
Operating manual on CD
Plastic carrying case
1X DA 501 EN Probe, 5 MHz, Contact Dia. .475 in / 12.1 mm
Meets EN specifications
1X KBA-533 Cable
Measuring range = 0.040 – 8.0 in / 1.2 – 200 mm in steel
Sch B # 9024.90.0000
Full Specifications
Operating principle Ultrasonic, pulse echo measurement method
Measuring range
Depends on probe and material, 0.60 mm to 508 mm (0.025” to 20.00”) in IP to 1st BW measurement mode,
2.00 mm to 127.0 mm (0.079” to 5.00”) in dual-multi measurement mode, the coating thickness range shall be 0.3 mm to 2.50 mm (0” to 0.098”).
Measuring resolution 0.01 mm default – selectable 0.01, 0.1 mm (0.001” default – selectable 0.001”, 0.01”)
Material velocity range 0.508 to 18.699 mm/msec (0.0200” to 0.7362”/msec)
Material velocity resolution 1 m/s (0.0001”/msec)
Units Inch or millimeter
Calibration One-point cal, on-block and off-block, two-point cal
Pulser
Excitation Pulse Spike pulser
Voltage 120 V into 50 ohm load, using 20 MHz oscilloscope
Receiver
Bandwidth 500 KHz to 12 MHz @ -3 dB
Gain Automatic gain control
Display type High-resolution graphical LCD, 64 x 128 pixels, 53.0 mm x 27.0 mm with backlight and adjustable contrast
Update rate 4 Hz or 8 Hz, user selectable, 24 Hz scan mode capture rate
Thickness value display
NORMAL view mode 5 Digit, 10.6 mm (0.4”) high
B-SCAN view mode 5 Digit, 2.55 mm (0.1”) high
Display of last reading Solid filled or hollow digits indicate coupled or uncoupled condition
Setups 9 standard setups for probes
Alarm settings Minimum and maximum alarms, range of 0.25 mm to 508 mm, 0. (0.010” to 20.00”) reading alternates between solid and hollow when alarms are enabled and violated
Power requirements 2 “AA” size batteries Battery life/ operating time Approximately 60 hours
Instrument shut-off Selectable ALWAYS ON or AUTO OFF after 5, 10, 15, 30 minutes of inactivity
Language Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese
I/O connectors
Transducer Dual Lemo 00 (coax)
Mini-USB Mini USB to PC
Temperature Operating -10°C to +50°C (+10°F to +120°F)
Storage -20°C to +60°C (-10°F to +140°F)
Weight 223 g (0.597 lb) including batteries
Size 138 mm x 32 mm x 75 mm
Shock IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms impulse half sinusoidal wave applied 6 times per axis
Sealing IEC529 / IP54, dust proof/dripping water proof as per IEC 529 specifications for IP54 classification
DM5E probe/transducer specifications
Frequency 5 MHz
Probe style Standard
temperature range (continuous) -20 to 70°C
Contact diameter 15 mm (0.590”)
IP to first measurement range 1.0 to 200 mm (0.040 to 8”)
Minimum multi-echo measurement range 3.0 to 100 mm (0.118 to 3.936”)
Valoraciones